ASTM E1012 PDF DOWNLOAD

Home» Testing Solutions» By Standard» ASTM» ASTM E Menu. Lists · ASTM D · ASTM D · ASTM C · ASTM A · ASTM D · ASTM. 10 Mar This standard is issued under the fixed designation E; the number 1 This practice is under the jurisdiction of ASTM Committee E28 on. 1 Jul ASTM E Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force.

Author: Goltiktilar Togore
Country: Sweden
Language: English (Spanish)
Genre: Literature
Published (Last): 8 September 2005
Pages: 33
PDF File Size: 15.79 Mb
ePub File Size: 11.5 Mb
ISBN: 841-9-70770-477-6
Downloads: 72706
Price: Free* [*Free Regsitration Required]
Uploader: Mubei

These methods are particularly applicable astm e1012 rates of loading astm e1012 used for tension testing, creep testing, and uniaxial fatigue testing. You can set you back stops to the required distance and by placing the sample in up against the back stops, you can ensure that the specimen is perfectly aligned every time. In the asym, none of the bending strains may exceed the allowables. These days, some machine manufacturers have helped ease the pain by producing and alignment fixture.

Notes are optional and private. It has been shown that bending stresses that inadvertently occur due to misalignment between the applied force and the specimen axes during the application of tensile and compressive forces can affect the test results. In addition astm e1012 aerospace manufacturers and service providers, an increasing number of companies in other sectors are affected by alignment measurement as part of Nadcap accreditation requirements, for example in the mechanical and plant engineering astm e1012 and in the metals astm e1012.

Figure 3 — Zwick grip alignment fixture Specimen gripping Figure 4 — Example of a specimen misaligned within the grips of a tensile machine So, you have made sure that your fibres and your grips are aligned, but that is only half the battle. Great care must go into ensuring astm e1012 correct alignment of a gauge on the specimen. Our standardized strain-gaged alignment transducer works with a large percentage of the materials testing machines to be tested. An experienced Zwick service technician positions the strain-gaged alignment transducer in the test axis of your testing system and it is then loaded in the elastic range.

In recognition of this effect, some test methods include a statement limiting AC for metallic materials, and AC for non-metallic materials. This line can then be used as a reference for machining. For all these reasons, astm e1012 the desired bending requirements can be challenging.

Only the most rigid, precision, and quality-made mechanical testing systems and grips can meet the bending requirements of NADCAP repeatably. Misalignment of the load train or the specimen leads to non-uniform force application resulting in additional bending or twisting forces being imparted on the specimen and erroneously low breaking forces.

Figure 2 — The effect astm e1012 misalignment on tensile strength of composites So how do we guarantee that we machine our astm e1012 in such a way that we get well aligned fibre?

With increasing recognition that testing systems must be properly aligned for the best test results, Instron’s alignment calibration service is now offered for most types of testing machines. In recognition of this effect, some test methods include a statement limiting the misalignment that is permitted. E Standard Terminology Relating to Metallography. The principal objective of this practice is to assess the amount of bending exerted upon a test specimen by the ordinary components assembled into a materials testing machine, during routine tests.

Referenced Documents purchase separately Astm e1012 documents listed below are referenced within the subject standard but are not provided as part of the standard. These astm e1012 are particularly applicable to the force levels normally used for tension testing, creep astm e1012, and uniaxial fatigue testing. The strain gauge outputs are monitored live to provide real time precise adjustment of the astm e1012 string to achieve minimum bending.

You have successfully saved to your supplier list. Notes are optional and private.

Alignment Measurement—Verifying Test Axis Alignment

This guide is not intended to be used instead of certified traceable calibration or verification of astm e1012 acquisition systems when such cert Remember me for one month.

Not only does misalignment deliver reduced results, but also a significant increase in the standard deviation of the results. Alternatively, Instron offers an “AlignPro” kit which fits between the load cell and the crosshead of the machine, which allows one to adjust the angular and axial alignment of the system while under load. These fibres that were astm e1012 for load bearing will therefore be unable to bear the loads required of them, ultimately reducing the load bearing capacity of the specimen and delivering reduced results.

No items astm e1012 cart. Note 1-These metric test methods are the equivalents astm e1012 those in Test Methods B, and are compatible in technical content except for the Subscribe to Instron News!

ASTM E – Instron

In the event of non-uniform force application to astm e1012 specimen, the applied strain gages will register different strains.